TT-BEAMS
Used as roof bearing structure in building the industrial, business and non-residential facilities.
AS Betoneks manufactures TT-beams pursuant to the requirements stipulated in standards EVS-EN 13224:2011 “Ribbed floor elements” and EVS EN 13369 “Common rules for precast concrete elements”. TT-beams are manufactured according to the measures and shape specified in the design documentation.
sample TT 240/20-80/12
H | A | C | D | E | sectional area | weight | weight |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | m2 | T/m | Kg/m2 |
200 | 162 | 120 | 514 | 1200 | 0,183 | 0,457 | 0,191 |
300 | 171 | 129 | 505 | 1209 | 0,21 | 0,525 | 0,22 |
400 | 180 | 138 | 496 | 1218 | 0,239 | 0,598 | 0,25 |
500 | 189 | 147 | 487 | 1227 | 0,27 | 0,676 | 0,283 |
600 | 198 | 156 | 478 | 1236 | 0,303 | 0,758 | 0,317 |
700 | 207 | 165 | 469 | 1245 | 0,338 | 0,844 | 0,353 |
800 | 216 | 174 | 460 | 1254 | 0,374 | 0,935 | 0,391 |
TT 240/20-80/17
TT 240/20-80/22
More information about steel details used in columns is available at Internet addresses:
Design work.
Initial data required from the client for designing or consultancy services: shape drawing of the beam of the required type, normative loads, required fire resistance, support joints, connection elements and locations thereof, loads applied on the structural elements concreted in the beam.